Appendix#
In REHO, most of the model parameters can be given through additional files. However, there are default values already implemented in the model. This appendix attempts to report them.
Units#
To define the units’ costs, the price per unit installed and the unit lifetime are considered. They are reported in Tables Building units default specifications and District units default specifications.
Unit |
ref_unit |
Units_Fmin |
Units_Fmax |
Cost_inv1 |
Cost_inv2 |
GWP_unit1 |
GWP_unit2 |
lifetime |
UnitOfType |
UnitOfLayer |
UnitOfService |
StreamsOfUnit |
Units_flowrate_in |
Units_flowrate_out |
stream_Tin |
stream_Tout |
References |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NG_Boiler |
kWth |
0.1 |
100000 |
5000 |
200 |
500 |
10 |
20 |
NG_Boiler |
NaturalGas/ HeatCascade |
DHW/ SH |
h_ht |
NaturalGas |
80 |
60 |
|
|
OIL_Boiler |
kWth |
0.1 |
100000 |
5000 |
175 |
500 |
10 |
20 |
OIL_Boiler |
Oil/ HeatCascade |
DHW/ SH |
h_ht |
Oil |
80 |
60 |
|
|
WOOD_Stove |
kWth |
0.1 |
100000 |
5000 |
150 |
400 |
10 |
20 |
WOOD_Stove |
Wood /HeatCascade |
SH |
h_ht |
Wood |
80 |
60 |
||
HeatPump_Air |
kWth |
0.1 |
100000 |
17500 |
400 |
1500 |
20 |
20 |
HeatPump |
HeatCascade/ Electricity |
DHW/ SH |
h_ht/ h_mt/ h_lt |
Electricity |
55/ 45/ 35 |
50/40/30 |
|
|
HeatPump_Geothermal |
kWth |
0.1 |
100000 |
37500 |
300 |
2500 |
15 |
20 |
HeatPump |
HeatCascade/ Electricity |
DHW/ SH |
h_ht/ h_mt/ h_lt |
Electricity |
55/ 45/ 35 |
50/40/30 |
|
|
HeatPump_DHN |
kWth |
0.1 |
100000 |
17500 |
300 |
1500 |
15 |
20 |
HeatPump |
HeatCascade/ Electricity/ Heat |
DHW/ SH |
h_ht/ h_mt/ h_lt |
Electricity/ Heat |
55/ 45/ 35 |
50/40/30 |
||
HeatPump_Lake |
kWth |
0.1 |
100000 |
17500 |
300 |
1500 |
15 |
20 |
HeatPump |
HeatCascade/ Electricity |
DHW/ SH |
h_ht/ h_mt/ h_lt |
Electricity |
55/ 45/ 35 |
50/40/30 |
||
AirConditioner |
kWth |
0.1 |
100000 |
3000 |
200 |
500 |
20 |
20 |
AirConditioner |
HeatCascade/ Electricity |
Cooling |
c_ht/ c_mt/ c_lt |
Electricity |
13/ 15/ 18 |
14/ 16/ 19 |
|
|
ElectricalHeater_other |
kWth |
0.1 |
100000 |
1000 |
50 |
100 |
5 |
20 |
ElectricalHeater |
HeatCascade/ Electricity |
rSOC_heat |
h_ht |
Electricity |
80 |
60 |
||
ElectricalHeater_SH |
kWth |
0.1 |
100000 |
1000 |
50 |
100 |
5 |
20 |
ElectricalHeater |
HeatCascade/ Electricity |
SH |
h_ht |
Electricity |
80 |
60 |
|
|
ElectricalHeater_DHW |
kWth |
0.1 |
100000 |
2000 |
100 |
200 |
5 |
20 |
ElectricalHeater |
HeatCascade/ Electricity |
DHW |
h_ht |
Electricity |
80 |
60 |
|
|
PV |
kWe |
0.1 |
100000 |
10000 |
1300 |
200 |
1000 |
30 |
PV |
Electricity |
Electricity |
|
|||||
ThermalSolar |
m2 |
0.1 |
100000 |
6000 |
800 |
500 |
75 |
20 |
ThermalSolar |
HeatCascade |
DHW |
h_ht |
62 |
48 |
|||
Battery |
kWh |
5 |
100000 |
5000 |
550 |
100 |
100 |
15 |
Battery |
Electricity |
Electricity |
Electricity |
|
||||
WaterTankSH |
L |
0.1 |
100000 |
2000 |
2 |
200 |
1 |
20 |
WaterTankSH |
HeatCascade |
SH |
h_ht/ c_lt |
35/ 35 |
35/ 35 |
|
||
WaterTankDHW |
L |
0.1 |
100000 |
2000 |
2 |
200 |
1 |
20 |
WaterTankDHW |
HeatCascade |
DHW |
c_ht |
10 |
60 |
|
||
DHN_hex |
m2 |
0.1 |
100000 |
6000 |
500 |
400 |
100 |
20 |
DHN_hex |
Heat/ HeatCascade |
SH/ DHW |
h_ht |
Heat |
80 |
60 |
|
|
DHN_pipes |
kW |
0.1 |
100000 |
10000 |
200 |
2000 |
10 |
60 |
DHN_pipes |
Heat |
|
||||||
DataHeat_SH |
kWth |
0.1 |
100000 |
1000 |
5000 |
1000 |
500 |
4 |
DataHeat |
Electricity/ Data/ HeatCascade |
SH |
h_ht |
Electricity |
Data |
80 |
60 |
|
DataHeat_DHW |
kWth |
0.1 |
100000 |
1000 |
11000 |
1000 |
500 |
4 |
DataHeat |
Electricity/ Data/ HeatCascade |
DHW |
h_ht |
Electricity |
Data |
80 |
60 |
|
MTR |
kW |
0.1 |
100000 |
15000 |
1000 |
2000 |
10 |
20 |
Methanator |
Biomethane/ CO2/ Hydrogen/ Electricity/ HeatCascade |
SH/ DHW/ rSOC_heat |
h_ht |
Hydrogen/ CO2/ Electricity |
Biomethane |
80 |
60 |
|
rSOC |
kW |
0.1 |
100000 |
20000 |
3000 |
3000 |
50 |
10 |
rSOC |
Electricity/ Hydrogen/ CO2/ Biomethane/ HeatCascade |
SH/ DHW/ rSOC_heat |
h_ht/ c_ht |
Hydrogen/ Biomethane/ Electricity |
Electricity/ CO2/ Hydrogen |
80/ 60 |
60/ 80 |
|
FC |
kW |
0.1 |
100000 |
15000 |
2000 |
2000 |
50 |
20 |
FuelCell |
Electricity/ Hydrogen/ HeatCascade |
SH |
h_ht |
Hydrogen |
Electricity |
80 |
60 |
|
ETZ |
kWh |
0.1 |
100000 |
10000 |
1000 |
2000 |
50 |
10 |
Electrolyzer |
Electricity/ Hydrogen/ HeatCascade |
SH |
h_ht |
Electricity |
Hydrogen |
80 |
60 |
Unit |
ref_unit |
Units_Fmin |
Units_Fmax |
Cost_inv1 |
Cost_inv2 |
GWP_unit1 |
GWP_unit2 |
lifetime |
UnitOfType |
UnitOfLayer |
UnitOfService |
StreamsOfUnit |
Units_flowrate_in |
Units_flowrate_out |
stream_Tin |
stream_Tout |
References |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Battery_district |
kWh |
100 |
100000 |
50000 |
200 |
10000 |
50 |
15 |
Battery |
Electricity |
Electricity |
Electricity |
|||||
EV_district |
kWh |
0.1 |
100000 |
6000 |
750 |
0 |
0 |
10 |
EV |
Mobility |
Mobility |
|
|||||
EV_charger_district |
kW |
0.1 |
100000 |
300 |
170 |
0 |
0 |
10 |
EV_charger |
Mobility/ Electricity |
Electricity |
Electricity |
|
||||
ICE_district |
number |
0 |
10000 |
0 |
40000 |
0 |
8000 |
10 |
ICE |
Mobility / Gasoline |
Gasoline |
Mobility |
|
||||
ElectricBike_district |
number |
0 |
1000 |
0 |
1200 |
0 |
200 |
10 |
EBike |
Mobility / Electricity |
Electricity |
Mobility |
|
||||
Bike_district |
number |
0 |
1000 |
0 |
200 |
0 |
75 |
10 |
Bike |
Mobility |
Mobility |
||||||
NG_Boiler_district |
kWth |
0.1 |
100000 |
21767 |
65 |
10000 |
5 |
30 |
NG_Boiler |
NaturalGas/ Heat |
NaturalGas |
Heat |
80 |
60 |
|
||
NG_Cogeneration_district |
kWth |
0.1 |
100000 |
50000 |
250 |
10000 |
10 |
30 |
NG_Cogeneration |
Heat/ Electricity/ NaturalGas |
NaturalGas |
Heat/ Electricity |
60 |
40 |
|
||
HeatPump_Geothermal_district |
kWth |
0.1 |
100000 |
75353 |
207 |
10000 |
10 |
30 |
HeatPump |
Heat/ Electricity |
Electricity |
Heat |
80 |
60 |
|
||
DHN_pipes_district |
kW |
0.1 |
100000 |
5670 |
613 |
0 |
0 |
60 |
DHN_pipes |
Heat |
|
||||||
rSOC_district |
kW |
0.1 |
100000 |
1000 |
3000 |
1500 |
10 |
10 |
rSOC |
Electricity/ Hydrogen/ CO2/ Biomethane/ Heat |
Hydrogen/ Biomethane/ Electricity/ Heat |
Electricity/ CO2/ Hydrogen/ Heat |
90 |
60 |
|||
MTR_district |
kW |
0.1 |
100000 |
1000 |
375 |
1000 |
10 |
20 |
Methanator |
Biomethane/ CO2/ Hydrogen/ Electricity/ Heat |
Hydrogen/ CO2/ Electricity |
Biomethane/ Heat |
90 |
60 |
|||
ElectricalHeater_other_district |
kWth |
0.1 |
100000 |
1000 |
50 |
100 |
5 |
20 |
ElectricalHeater_Heat |
Heat/ Electricity |
Electricity |
Heat |
80 |
60 |
|||
Datacenter_district |
kW |
0.1 |
100000 |
100000 |
6000 |
0.00001 |
0 |
4 |
DataHeat |
Electricity/Data/ Heat |
Electricity |
Data/ Heat |
75 |
60 |
https://www.se.com/ww/en/work/solutions/system/s1/data-center-and-network-systems/trade-off-tools/data-center-capital-cost-calculator/ |
||
ORC_DC_district |
kW |
0.1 |
100000 |
75353 |
207 |
10000 |
10 |
30 |
ORC_DC_district |
Heat/ Electricity |
Heat |
Electricity |
Grids#
Grid |
ref_unit |
Network_demand_connection |
Network_supply_connection |
Cost_demand_cst |
Cost_supply_cst |
GWP_demand_cst |
GWP_supply_cst |
Cost_connection |
Network_ext |
ReinforcementOfNetwork |
Cost_network_inv1 |
Cost_network_inv2 |
GWP_network_1 |
GWP_network_2 |
Network_lifetime |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electricity |
kWh |
1 |
1 |
0.17 |
0.33 |
0.13 |
0.13 |
0 |
400 |
400/600/1000/2000 |
15000 |
10 |
0 |
0 |
60 |
NaturalGas |
kWh |
0 |
1 |
0 |
0.14 |
0 |
0.23 |
0 |
5000 |
500/1000/2000/5000 |
0 |
0 |
0 |
0 |
60 |
Oil |
kWh |
0 |
1 |
0 |
0.14 |
0 |
0.28 |
0 |
5000 |
500/1000/2000/5000 |
0 |
0 |
0 |
0 |
60 |
Heat |
kWh |
1 |
1 |
0 |
0.15 |
0 |
0.23 |
0 |
5000 |
500/1000/2000/5000 |
0 |
0 |
0 |
0 |
60 |
Wood |
kWh |
0 |
1 |
0 |
0.11 |
0 |
0.10 |
0 |
5000 |
500/1000/2000/5000 |
0 |
0 |
0 |
0 |
60 |
Hydrogen |
kWh |
1 |
1 |
0.15 |
0.45 |
0.328 |
0.328 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
60 |
Biomethane |
kWh |
0 |
0 |
0 |
0.2 |
0 |
0.214 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
60 |
CO2 |
mol |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
60 |
Data |
kWh |
1 |
1 |
0.45 |
0.5 |
0 |
1.6 |
0 |
5000 |
500/1000/2000/5000 |
0 |
0 |
0 |
0 |
60 |
Mobility |
pkm |
0 |
1 |
0 |
0.4 |
0 |
0.0195 |
0 |
5000 |
500/1000/2000/5000 |
0 |
0 |
0 |
0 |
60 |
Gasoline |
kWh |
0 |
1 |
0 |
0.19 |
0 |
0.485 |
0 |
5000 |
500/1000/2000/5000 |
0 |
0 |
0 |
0 |
60 |
Mobility#
label |
description |
source |
|---|---|---|
demwdy_def |
demand profile of a weekday [-] |
OFS G 3.1.3 + G 3317 |
demwnd_def |
demand profile of a weekend day [-] |
OFS G 3.1.3 + G 3317 |
EV_cpfwdy |
charging profile of EVs during a weekday [-] |
UK data on charging stations |
EV_cpfwnd |
charging profile of EVs during the weekend [-] |
UK data on charging stations |
EV_outwdy |
share of EVs unplugged during a weekday |
UK data on charging stations |
EV_outwnd |
share of EVs unplugged during a weekend day |
UK data on charging stations |
Bike_prfwdy |
supply profile for bikes during a weekday [-] |
OFS G3.3.1.7 |
Bike_prfwnd |
supply profile for bikes during a weekend [-] |
OFS G3.3.1.7 |
EV_aworkwdy |
share of the EV fleet located at a work place during a weekday |
|
EV_atravelwdy |
share of the EV fleet travelling during a weekday |
|
EV_aleisurewdy |
share of the EV fleet located at a leisure place during a weekday |
|
EV_aleisurewnd |
share of the EV fleet located at a leisure place during the weekend |
|
EV_aworkwnd |
share of the EV fleet located at a work place during the weekend |
|
EV_atravelwnd |
share of the EV fleet travelling during the weekend |
|
EBike_cpfwdy |
charging profile of electric bikes during a weekday [-] |
|
EBike_cpfwnd |
charging profile of electric bikes during a weekday [-] |
A focus on mobility units and streams at the district-level#